The system is
designed to automatically reduce acid levels in a flow line,
following a
well stimulation operation. The Instrumentation System
monitors acid levels in a flow line and automatically controls neutralising
dose through a proportional control valve.
Feedback from a
pH sensor provides automatic control of the output of the
dosing pump speed via a proportional control valve. This process
uses a loop controller to get pH level of the returns acceptably
close to 5.5.
Data is
displayed. Manual override of dosing is available.
The pH sensor
is suitable for operation in a Zone 1 hazardous area; the Pump
Unit, Data Processing and Display Unit are safe area equipment,
with hazardous area options available.
Typical
System Hardware
Sensors
-
Flow sensor. In-line
flow sensor for up to 25 litres per minute on the 1" line
pump dosage line.
-
Pressure sensor, 0
– 1,000 psi
-
pH sensor for range
from HC acid to 5.5. This is configured in a sub-frame for
connection to the process line via ˝" NB fittings.
-
Low level tank float
switch
-
High level tank
float switch
Data Processing,
Displays and Alarms
Data processing takes place in a stainless steel enclosure, which
accommodates the system’s power supply unit, pH loop controller and
safety barriers. This enclosure can be located at any convenient
location, preferably in a sheltered location, out of direct sunshine,
where it can be readily accessed, if necessary.
Fittings, Hoses
Lengths of flexible return hose is supplied, with fittings, to
transport the neutralized, sampled fluid to temporary storage, prior
to re-injection or disposal.
To discuss further, or obtain
quotation please either complete enquiry
form or call on numbers above.
|
|
|